2423 Maryland Ave, Suite 200
Baltimore, MD 21218
410 235-8303

BID OPPORTUNITIES

Jared Burkett

Locust Grove Sewage Pumping Station ITB - Braddock Run-Jennings Run Sewage Conveyance Improvements - Locust Grove Sewage Pumping Station Replacement

About this Bid:

The Project generally consists of constructing a new 8.8 MGD sewage pumping station with three (3) dry pit submersible pumps, two (2) influent channel grinders, cast-in-place wet well and dry well, above ground brick and block building with standing seam metal roof, relocated activated carbon odor control system, chemical dosing systems, standby generator, electrical distribution equipment, VFDs, controls and instrumentation, 20-inch diameter force main, site work and demolition of existing pumping station.




Bid Start Date:

Bid End Date: 11/16/2020

Bid Time: 12:00pm

Special Instructions:

N/A


 

File Attachment(s)

Phone: (301) 729-8900



Location:

Maryland
United States
Map It

Kareen Davis

MBE Notification for MAA-MC-21-006 Asbestos, Lead-Based Paint, Mold Remediation, Containment and Abatement Services at BWI Thurgood Marshall and MTN Airports

About this Bid:

n our effort to assure minority businesses of every opportunity to be considered for contract awards for work at the Maryland Department of Transportation Maryland Aviation Administration (MDOT MAA), we are pleased to provide you the attached Notice to Contractors.

 




Bid Start Date:

Bid End Date:

Bid Time:

Special Instructions:

N/A


 

File Attachment(s)

Phone: (410) 859-7792



Location:

Maryland
United States
Map It

Dave Snyder

Locust Grove Force Main and LaVale Water Main Replacement ITB

About this Bid:

The Project generally consists of constructing approximately 3,300 linear feet of buried 20-inch diameter PVC force main piping; 4,800 linear feet of buried 24-inch diameter PVC main piping, 210 linear feet of above ground (bridge crossing) 20-inch diameter main ductile iron piping, 1,750 linear feet of above ground 24-inch diameter ductile iron piping, pipe supports, valves, other various pipe appurtenances,

retaining wall replacement, 5,100 linear feet of 12-Inch PVC water main, 140 linear feet of 10-Inch PVC water main, 185 linear feet of above ground (bridge crossing) 10-inch diameter water ductile iron piping, retaining wall replacement and restoration.




Bid Start Date: 11/09/2020

Bid End Date: 11/09/2020

Bid Time: 12:00 Noon

Special Instructions:

N/A


 

Phone: (301) 729-8900



Location:

Maryland
United States
Map It